RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rydberg, J.
Right arrow Articles by Kopecky, K. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rydberg, J.
Right arrow Articles by Kopecky, K. K.
Related Collections
Right arrow Computed Tomography
Right arrow Physics and Basic Science
(Radiographics. 2000;20:1787-1806.)
© RSNA, 2000


IMAGING & THERAPEUTIC TECHNOLOGY

Multisection CT: Scanning Techniques and Clinical Applications1

Jonas Rydberg, MD, Kenneth A. Buckwalter, MD, Karen S. Caldemeyer, MD, Michael D. Phillips, MD, Dewey J. Conces, Jr, MD, Alex M. Aisen, MD, Scott A. Persohn, RT and Kenyon K. Kopecky, MD

1 From the Department of Radiology, Indiana University School of Medicine, Indianapolis. Recipient of a Certificate of Merit award for a scientific exhibit at the 1999 RSNA scientific assembly. Received March 1, 2000; revision requested April 11; final revision received June 22; accepted July 6. Address correspondence to K.K.K., Department of Radiology, Indiana University Hospital, Rm 0615, 550 N University Blvd, Indianapolis, IN 46202-5253 (e-mail: kkopecky@iupui.edu).

Multisection computed tomography (CT) was introduced in 1992 with the advent of dual-section–capable scanners and was improved in 1998 following the development of quad-section technology. With a recent increase in gantry speed from one to two revolutions per second, multisection CT scanners are now up to eight times faster than conventional single-section helical CT scanners. The benefits of quad-section CT relative to single-section helical CT are considerable. They include improved temporal resolution, improved spatial resolution in the z axis, increased concentration of intravascular contrast material, decreased image noise, efficient x-ray tube use, and longer anatomic coverage. These factors substantially increase the diagnostic accuracy of the examination. The multisection CT technique has enabled faster and superior evaluation of patients across a wide spectrum of clinical indications. These include isotropic viewing, musculoskeletal applications, use of multiplanar reformation in special situations, CT myelography, long coverage and multiphase studies, CT angiography, cardiac scoring, evaluation of brain perfusion, imaging of large patients, evaluation of acute chest pain or dyspnea, virtual endoscopy, and thin-section scanning with retrospective image fusing. Multisection CT is superior to single-section helical CT for nearly all clinical applications.

Index Terms: Computed tomography (CT), helical • Computed tomography (CT), technology • Computed tomography (CT), thin-section




This article has been cited by other articles:


Home page
BloodHome page
T. C. Kwee, R. M. Kwee, and R. A. J. Nievelstein
Imaging in staging of malignant lymphoma: a systematic review
Blood, January 15, 2008; 111(2): 504 - 516.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
R. M. Kwee and T. C. Kwee
Imaging in Local Staging of Gastric Cancer: A Systematic Review
J. Clin. Oncol., May 20, 2007; 25(15): 2107 - 2116.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. van Straten, H.W. Venema, C.B.L.M. Majoie, N.J.M. Freling, C.A. Grimbergen, and G.J. den Heeten
Image Quality of Multisection CT of the Brain: Thickly Collimated Sequential Scanning versus Thinly Collimated Spiral Scanning with Image Combining
AJNR Am. J. Neuroradiol., March 1, 2007; 28(3): 421 - 427.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. P. N. Chan, H. H. Abujudeh, G. L. Cushing Jr., and R. A. Novelline
CT cystography with multiplanar reformation for suspected bladder rupture: experience in 234 cases.
Am. J. Roentgenol., November 1, 2006; 187(5): 1296 - 1302.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. M. Remer, G. A. Motta-Ramirez, L. B. Shepardson, A. H. Hamrahian, and B. R. Herts
CT histogram analysis in pathologically proven adrenal masses.
Am. J. Roentgenol., July 1, 2006; 187(1): 191 - 196.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Rastogi, D. V. Sahani, M. A. Blake, D. C. Ko, and P. R. Mueller
Evaluation of Living Renal Donors: Accuracy of Three-dimensional 16-Section CT
Radiology, July 1, 2006; 240(1): 136 - 144.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. A. Jaffe, R. C. Nelson, G. A. Johnson, E. R. Lee, T. T. Yoshizumi, C. R. Lowry, A. B. Bullard, D. M. DeLong, and E. K. Paulson
Optimization of Multiplanar Reformations from Isotropic Data Sets Acquired with 16-Detector Row Helical CT Scanner
Radiology, January 1, 2006; 238(1): 292 - 299.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. A. Jaffe, L. C. Martin, J. Thomas, A. R. Adamson, D. M. DeLong, and E. K. Paulson
Small-Bowel Obstruction: Coronal Reformations from Isotropic Voxels at 16-Section Multi-Detector Row CT
Radiology, December 1, 2005; 238(1): 135 - 142.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Ohashi, G. Y. El-Khoury, D. L. Bennett, J. M. Restrepo, and K. S. Berbaum
Orthopedic Hardware Complications Diagnosed with Multi-Detector Row CT
Radiology, November 1, 2005; 237(2): 570 - 577.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. C. J. M. Kock, M. E. A. P. M. Adriaensen, P. M. T. Pattynama, M. R. H. M. van Sambeek, H. van Urk, T. Stijnen, and M. G. M. Hunink
DSA versus Multi-Detector Row CT Angiography in Peripheral Arterial Disease: Randomized Controlled Trial
Radiology, November 1, 2005; 237(2): 727 - 737.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. H. Baroni, D. Feller-Kopman, M. Nishino, H. Hatabu, S. H. Loring, A. Ernst, and P. M. Boiselle
Tracheobronchomalacia: Comparison between End-expiratory and Dynamic Expiratory CT for Evaluation of Central Airway Collapse
Radiology, May 1, 2005; 235(2): 635 - 641.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. J. Chung, K. C. Huh, W. J. Choi, and J. K. Kim
CT Colonography Using 16-MDCT in the Evaluation of Colorectal Cancer
Am. J. Roentgenol., January 1, 2005; 184(1): 98 - 103.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
V. V. Haapamaki, M. J. Kiuru, and S. K. Koskinen
Ankle and Foot Injuries: Analysis of MDCT Findings
Am. J. Roentgenol., September 1, 2004; 183(3): 615 - 622.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
F. Cademartiri, R. H. J. M. Raaijmakers, J. W. Kuiper, L. C. van Dijk, P. M. T. Pattynama, and G. P. Krestin
Multi-Detector Row CT Angiography in Patients with Abdominal Angina
RadioGraphics, July 1, 2004; 24(4): 969 - 984.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
B. F. Tomandl, N. C. Kostner, M. Schempershofe, W. J. Huk, C. Strauss, L. Anker, and P. Hastreiter
CT Angiography of Intracranial Aneurysms: A Focus on Postprocessing
RadioGraphics, May 1, 2004; 24(3): 637 - 655.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. A. S. Ianora, M. Memeo, C. Sabba, A. Cirulli, A. Rotondo, and G. Angelelli
Hereditary Hemorrhagic Telangiectasia: Multi-Detector Row Helical CT Assessment of Hepatic Involvement
Radiology, January 1, 2004; 230(1): 250 - 259.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. J. Siegel
Multiplanar and Three-dimensional Multi-Detector Row CT of Thoracic Vessels and Airways in the Pediatric Population
Radiology, December 1, 2003; 229(3): 641 - 650.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
P. Henrot, A. Blum, B. Toussaint, P. Troufleau, J. Stines, and J. Roland
Dynamic Maneuvers in Local Staging of Head and Neck Malignancies with Current Imaging Techniques: Principles and Clinical Applications
RadioGraphics, September 1, 2003; 23(5): 1201 - 1213.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. M. Boiselle, G. Dippolito, J. Copeland, H. Kang, M. Ahmed, D. Weeks, E. Halpern, and S. N. Goldberg
Multiplanar and 3D Imaging of the Central Airways: Comparison of Image Quality and Radiation Dose of Single- Detector Row CT and Multi- Detector Row CT at Differing Tube Currents in Dogs
Radiology, July 1, 2003; 228(1): 107 - 111.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
B. F. Tomandl, E. Klotz, R. Handschu, B. Stemper, F. Reinhardt, W. J. Huk, K.E. Eberhardt, and S. Fateh-Moghadam
Comprehensive Imaging of Ischemic Stroke with Multisection CT
RadioGraphics, May 1, 2003; 23(3): 565 - 592.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. S. Lee, T. K. Kim, J. H. Byun, H. K. Ha, P. N. Kim, A. Y. Kim, S. G. Lee, and M.-G. Lee
Hepatic Arteries in Potential Donors for Living Related Liver Transplantation: Evaluation with Multi-Detector Row CT Angiography
Radiology, May 1, 2003; 227(2): 391 - 399.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Ofer, S. S. Nitecki, S. Linn, M. Epelman, D. Fischer, T. Karram, D. Litmanovich, H. Schwartz, A. Hoffman, and A. Engel
Multidetector CT Angiography of Peripheral Vascular Disease: A Prospective Comparison with Intraarterial Digital Subtraction Angiography
Am. J. Roentgenol., March 1, 2003; 180(3): 719 - 724.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
M.P. Di Simone, S. Mattioli, F. D'Ovidio, and F. Bassi
Three-dimensional CT imaging and virtual endoscopy for the placement of self-expandable stents in oesophageal and tracheobronchial neoplastic stenoses
Eur. J. Cardiothorac. Surg., January 1, 2003; 23(1): 106 - 108.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Kozuka, T. Johkoh, S. Hamada, H. Naito, N. Tomiyama, M. Koyama, N. Mihara, O. Honda, H. Nakamura, and M. Kudo
Detection of Pulmonary Metastases with Multi-Detector Row CT Scans of 5-mm Nominal Section Thickness: Autopsy Lung Study
Radiology, January 1, 2003; 226(1): 231 - 234.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. P. Frush, C. C. Slack, C. L. Hollingsworth, G. S. Bisset, L. F. Donnelly, J. Hsieh, T. Lavin-Wensell, and J. R. Mayo
Computer-Simulated Radiation Dose Reduction for Abdominal Multidetector CT of Pediatric Patients
Am. J. Roentgenol., November 1, 2002; 179(5): 1107 - 1113.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. A. Haider, M. M. Amitai, D. C. Rappaport, M. E. O'Malley, A. E. Hanbidge, M. Redston, G. A. Lockwood, and S. Gallinger
Multi-Detector Row Helical CT in Preoperative Assessment of Small (<=1.5 cm) Liver Metastases: Is Thinner Collimation Better?
Radiology, October 1, 2002; 225(1): 137 - 142.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
H. K. Kang, Y. Y. Jeong, J. H. Choi, S. Choi, T. W. Chung, J. J. Seo, J. K. Kim, W. Yoon, and J. G. Park
Three-dimensional Multi-Detector Row CT Portal Venography in the Evaluation of Portosystemic Collateral Vessels in Liver Cirrhosis
RadioGraphics, September 1, 2002; 22(5): 1053 - 1061.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. M. Boiselle, K. F. Reynolds, and A. Ernst
Multiplanar and Three-Dimensional Imaging of the Central Airways with Multidetector CT
Am. J. Roentgenol., August 1, 2002; 179(2): 301 - 308.
[Full Text] [PDF]


Home page
RadiologyHome page
M. Macari, E. J. Bini, X. Xue, A. Milano, S. S. Katz, D. Resnick, H. Chandarana, G. Krinsky, K. Klingenbeck, C. H. Marshall, et al.
Colorectal Neoplasms: Prospective Comparison of Thin-Section Low-Dose Multi-Detector Row CT Colonography and Conventional Colonoscopy for Detection
Radiology, August 1, 2002; 224(2): 383 - 392.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
P. R. Ros and H. Ji
Special Focus Session: Multisection (Multidetector) CT: Applications in the Abdomen
RadioGraphics, May 1, 2002; 22(3): 697 - 700.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. P. Frush, B. Soden, K. S. Frush, and C. Lowry
Improved Pediatric Multidetector Body CT Using a Size-Based Color-Coded Format
Am. J. Roentgenol., March 1, 2002; 178(3): 721 - 726.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
K. M. Horton and E. K. Fishman
Volume-rendered 3D CT of the Mesenteric Vasculature: Normal Anatomy, Anatomic Variants, and Pathologic Conditions
RadioGraphics, January 1, 2002; 22(1): 161 - 172.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
K. M. Horton and E. K. Fishman
Multi-Detector Row CT of Mesenteric Ischemia: Can It Be Done?
RadioGraphics, November 1, 2001; 21(6): 1463 - 1473.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
B. F. Tomandl, P. Hastreiter, C. Rezk-Salama, K. Engel, T. Ertl, W. J. Huk, R. Naraghi, O. Ganslandt, C. Nimsky, and K. E. W. Eberhardt
Local and Remote Visualization Techniques for Interactive Direct Volume Rendering in Neuroradiology
RadioGraphics, November 1, 2001; 21(6): 1561 - 1572.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
H. Ji, J. D. McTavish, K. J. Mortele, W. Wiesner, and P. R. Ros
Hepatic Imaging with Multidetector CT
RadioGraphics, October 1, 2001; 21(90001): S71 - 80.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. Rydberg, K. K. Kopecky, M. Tann, S. A. Persohn, S. B. Leapman, R. S. Filo, and A. L. Shalhav
Evaluation of Prospective Living Renal Donors for Laparoscopic Nephrectomy with Multisection CT: The Marriage of Minimally Invasive Imaging with Minimally Invasive Surgery
RadioGraphics, October 1, 2001; 21(90001): S223 - 236.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. El-Sheik, J. T. Heverhagen, H. Alfke, J. J. Froelich, J. Hornegger, T. Brunner, K. J. Klose, and H.-J. Wagner
Multiplanar Reconstructions and Three-dimensional Imaging (Computed Rotational Osteography) of Complex Fractures by Using a C-arm System: Initial Results
Radiology, December 1, 2001; 221(3): 843 - 849.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOGRAPHICS RADIOLOGY RSNA JOURNALS ONLINE
Copyright © 2000 by the Radiological Society of North America.