EDUCATION EXHIBIT |
1 From the Department of Radiology, Mount Sinai Medical Center, 4300 Alton Rd, Miami Beach, FL 33140. Recipient of a Certificate of Merit award for an education exhibit at the 2002 RSNA scientific assembly. Received March 6, 2003; revision requested April 4 and received May 23; accepted May 27. All authors have no financial relationships to disclose. Address correspondence to L.E.E. (e-mail: lesserma@salick.com).
Directional vacuum-assisted biopsy has become an irreplaceable tool in the management of suspicious mammographic lesions. Often, the entire lesion is removed and clips are used to localize the biopsy site. Postbiopsy mammograms are used to determine the adequacy of clip placement and the location of the clip. Clip displacement from the site of deployment is not an uncommon finding. Clips may migrate within the same quadrant where the lesion was located or to another quadrant of the breast. Clip migration may occur immediately after biopsy or may be seen on later follow-up mammograms. Clip migration can affect interpretation of mammographic findings and localization for future surgery. It should not be assumed that the clip is correctly located at the biopsy site on subsequent mammograms. It is essential to recognize the relationship of the clip to the targeted lesion to ensure accurate localization of lesions that require surgical excision.
© RSNA, 2004
Index Terms: Biopsies, complications, 00.126, 00.458 Biopsies, technology, 00.126 Breast, biopsy, 00.126 Breast neoplasms, localization, 00.125 Foreign bodies, 00.4537
This article has been cited by other articles:
![]() |
C. L. Mercado, A. A. Guth, H. K. Toth, L. Moy, D. Axelrod, and J. Cangiarella Sonographically Guided Marker Placement for Confirmation of Removal of Mammographically Occult Lesions After Localization Am. J. Roentgenol., October 1, 2008; 191(4): 1216 - 1219. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. L. Rahman, S. Crawford, A. Larkin, and R. Quinlan Superiority of Sonographic Hematoma Guided Resection of Mammogram Only Visible Breast Cancer: Wire Localization Should be an Exception Not the Rule Ann. Surg. Oncol., August 1, 2007; 14(8): 2228 - 2232. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Layeequr Rahman, E. Iuanow, S. Crawford, and R. Quinlan Sonographic Hematoma-Guided vs Wire-Localized Lumpectomy for Breast Cancer: A Comparison of Margins and Volume of Resection Arch Surg, April 1, 2007; 142(4): 343 - 346. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Parikh Delayed Migration of Gel Mark Ultra Clip Within 15 Days of 11-Gauge Vacuum-Assisted Stereotactic Breast Biopsy Am. J. Roentgenol., July 1, 2005; 185(1): 203 - 206. [Full Text] [PDF] |
||||
![]() |
D. M. Lanners, K. K. Amrami, R. S. Jonsgaard, J. J. Gisvold, and J. P. Felmlee Safety and MRI Artifact Evaluation at 1.5 T of Metallic Mounting Sheath of a Marking Clip Inadvertently Deployed at Stereotactic Biopsy Am. J. Roentgenol., September 1, 2004; 183(3): 825 - 829. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOGRAPHICS | RADIOLOGY | RSNA JOURNALS ONLINE |